PRODUCT OVERVIEW
This product is mainly used in photovoltaic distributed grid-connected power generation system, which
is connected in series between grid-connected inverter and grid. The product has a series of
protections such as grid low voltage, grid overvoltage, input lightning protection, system overcurrent,
grid isolation, etc. Accurate electric energy metering, transmission and intelligent operation control are
essential parts of household grid-connected power generation system. The product has passed CCC
certification, CE certification, ISO9001 quality management system certification, etc.
MAIN CHARACTERISTICS:
Reserve the installation position of metering meter and collector;
Visual window and lead seal of metering meter (anti-electricity stealing);
The integrated design concept of the product, the power distribution part is completely isolated from the metering part, and the electromagnetic interference is reduced;
Special photovoltaic molded case reclosing circuit breaker, with more reliable performance;
It can be matched with on-line power quality monitoring and islanding protection device, fault
disconnection device, etc;
Optional outdoor and indoor installation, making installation more convenient;
Support special requirements and function customization.
TECHNICAL PARAMETERS
| Product model | SPGC-5KNB | SPGC-10KNB |
| Matching inverter power | 3KW、5KW | 8KW、2*5KW |
| Number of inverter input channels | 1-channel | 1-channel /2-channel |
| Grid-connected output channels | 1-channel | |
| Grid connection requirement | Single-phase grid-connected | |
| Grid voltage | 220Vac | |
| Switching capacity | 32A | 63A |
| Protective function | ||
| Short circuit protection | Yes | |
| Lightning protection | Yes (nominal current: In: 20KA, Imax: 40KA, Up≤4KV) | |
| Isolation protection (visual breakpoint) | Yes (breaker/hand-pulled disconnector) | |
| Overvoltage and undervoltage protection | Yes | |
| Auto-reclosing | Yes | |
| Grid-connected switch | ||
| Self resetting overvoltage and undervoltage protector | 1. When the power grid is cut off or the bias voltage is greater than 20%, it will automatically disconnect (internal disconnection); 2. When the power grid returns to normal, it will automatically close (internal connection); | |
| Special photovoltaic reclosing circuit breaker | 1. When the power grid is cut off or the bias voltage is greater than 20%, it will automatic break-brake (operation handle action); 2. When the power grid returns to normal, it will automatically switch on (operating the handle); 3. Manual operation and automatic operation can be switched; | |
| Changshu molded case reclosing | 1. When the power grid is cut off or the bias voltage is greater than 20%, it will automatically trip (the delay tripping time is adjustable from 0 to 0~10S); 2. When the power grid returns to normal, automatic switching; 3. Manual operation and automatic operation can be switched; | |
| Environmental applicability | ||
| Temperature and humidity | Operating temperature: -25 to +60℃ Storage temperature: -40 to +70℃ Humidity: 0-90% without condensation. Places without corrosive gas (if any, please specify) | |
| Use altitude | ≤3000M | |
| 耐盐雾 Salt spray resistance | Salt spray test is standard for 336 hours. | |
| Conventional parameters | ||
| Material | Stainless steel, cold-rolled sheet spray molding, stainless steel spray molding. | |
| the protection grades | Outdoor IP55 | |
| Box type | Double doors with meter positions (distribution warehouse and metering warehouse) | |
| Installation mode | Wall mounting type | |
| Box size (length * width * height) | 610mm*430mm*150mm | |
| Reference weight | 10 kg | |