JP SERIES POWER DISTRIBUTION CABINET

+ More Information

KYN28A-24 Electrical Circuit Control Monitoring Power Switchgear

Product Overview KYN28A-24(Z)(GZS1) armored withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switching device”), suitable for three-phase AC The 50Hz power system is used to receive and distribute electrical energy and control, protect and monitor the circuit. This product conforms to the standard: GB3906-2006 “3.6-40. 5KV AC metal-enclosed switchgear and control equipment”, GB /T11022 “High […]

Product Overview

KYN28A-24(Z)(GZS1) armored withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switching device”), suitable for three-phase AC The 50Hz power system is used to receive and distribute electrical energy and control, protect and monitor the circuit. This product conforms to the standard: GB3906-2006 “3.6-40. 5KV AC metal-enclosed switchgear and control equipment”, GB /T11022 “High voltage Common Technical Requirements for Switchgear and Control Equipment Standards”, IEC60298 “AC metal-enclosed switchgear with rated voltage above 1KV and below 52KV Control Equipment”, DL/T404 “Technical Conditions for Ordering Indoor AC High Voltage Switchgear”.

Model Meaning

● Install a vacuum circuit breaker
● Rated voltage (KV)
● Design Number
● indoor
● Withdrawable
● Armoured

Normal use environmental conditions

1. Ambient air temperature: the highest temperature is 40°C, the lowest temperature is -15°C.
2. Humidity conditions:
Daily average relative humidity: ≤95%, daily average water vapor pressure does not exceed 2.2Kpa;
Monthly average relative humidity: ≤90%, monthly average water vapor pressure does not exceed 1.8Kpa;
3. Altitude: 1000m and below.
4. Earthquake intensity: no more than 8 degrees.
5. The surrounding air should not be significantly polluted by corrosive or combustible gas, water vapor, etc.
6. There is no frequent severe vibration place.
7. When used under normal environmental conditions exceeding GB3906, it shall be negotiated by the user and the manufacturer;

Technical parameters (see Table 1)

ProjectUnitData
Rated voltageKV3.6、7.2、12、24
Rated frequencyHz50
Circuit breaker rated currentA630、1250、1600、2000、2500、3150、4000
Rated current of switchgearA630、1250、1600、2000、2500、3150、4000
Rated short-time withstand current (4s)KA16、20、25、31.5、40、50
Rated peak withstand current (peak value)KA40、50、63、80、100、25
Rated short-circuit breaking currentKA16、20、25、31.5、40、50
Rated short-circuit making current (peak value)KA40、50、63、80、100、25
Rated insulation level1min power frequency withstand voltageBetween poles, betweenpoles to groundKV24、32、42、65
FractureKV24、32、48、79
Lightning impulse withstand voltage(peak value)Between poles, betweenpoles to groundKV40、60、75、125
FractureKV46、70、85、145
Protection leveThe shell is IP4X,and when the door of the next door and circuit breaker room is opened, it is IP4X
Note: 1. The short-circuit capacity of the current transformer is considered separately;
2. The technical parameters of VS1-24 are detailed in the corresponding samples of our company

Product structure characteristics

1. Switchgear structure (see Figure 1).
2. Completely metal armored, assembled structure, wide combination schemes.
3. The cabinet body is made of imported aluminum-zinc coated thin steel plate, processed by MINGE machine tools, and adopts advanced
Multi-folding process, connected with blind rivet nuts and high-strength bolts, with high precision, light weight and strong High degree of
accuracy and strong versatility of parts.
4. It can be equipped with VS1-24 series or imported VD4 series vacuum circuit breaker, which has wide applicability and reliability.
High performance, to achieve long-term maintenance-free.
5. The handcart is equipped with working and test positions, and each position has positioning and display devices, which is safe and reliable.
6. All kinds of handcarts can be changed according to modular building blocks to ensure that cars of the same specification can be freely
interchanged, with different specifications Cars must never enter.
7. Installation method of earthing switch
1) Installed in the middle of the cabinet (front-mounted) to facilitate double-sided maintenance after the cabinet (Figure 1-a).
2) Installed at the back of the cabinet (rear-mounted) to save space and area against the wall (Figure 1-b).
8. Current transformer installation method:
1) The cable room at the rear of the cabinet is installed.
2) Hoisting at the bottom of the large curved plate.
9. Up to 9 single-core cables can be installed in the cable room.
10. Each high-pressure chamber has a pressure relief channel to ensure personal safety.
11. The highly reliable interlocking device fully meets the “five prevention” safety requirements.
12. The handcart is transported by a special carrier, which is easy to operate and flexible.
13. The front and rear doors are equipped with observation windows, which can facilitate the observation of the working status of the indoor
components

A、Busbar room

B、Circuit breaker handcart room

C、Cable room.

D、Relay instrument room.

1、Shell

2、Branch bus

3、Bus bushing

4、Main bus

5、Static contact device

6、Contact box

7、Current Transformer

8、Earthing switch

9、Cable

10. Lightning arrester

11. Ground bus

12. Loading and unloading partitions

13. Partition (trap)

14. Secondary plug

15. Circuit breaker handcart

16. Heating device

17. Withdrawable horizontal partition

18. Grounding switch operating mechanism

19. Bottom plate

20. Pressure relief device

21. Control wire duct

Dimensions (see Figure 2 and Table 2)

Height B 2430
Height ARated current of branch small busbar ≤1250A, thermal stability current 40KA1000
Rated current of branch small busbar ≥1600A1000
Height CCable in and out1810
Overhead incoming and outgoing lines2170

Dimensions (see Figure 3,table 3 )

(mm)Table 3
Cabinet width ACabinet depth CL1L2L3L4
10001500 cable730830150800
2170 overhead7308303101160

Order notice

1. The main circuit diagram number, purpose and single-line system diagram, rated voltage, rated current, rated short-circuit breaking current, distribution room layout and switchgear arrangement diagram, etc.
2. Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices.
3. The model, specification and quantity of the main electrical components in the switchgear.
4. If the busbar bridge connection is required between switchgear or the incoming cabinet, the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, the height from the ground and other specific requirements data should be provided.
5. When the switchgear is used under special environmental conditions, it should be explained in detail when ordering.
6. Other special requirements.