JP SERIES POWER DISTRIBUTION CABINET

+ More Information

KYN28A-12 3 Phase Power Distrbuting Combined Switchgear Cabinet

Product overview KYN28A-12(Z)(GZS1) armored withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switching device”), suitable for three-phase AC The 50Hz power system is used to receive and distribute electrical energy and control, protect and monitor the circuit.This product conforms to the standard: GB3906 “3.6-40.5KV AC metal-enclosed switchgear and control equipment”, GB /T11022 “High-voltage switchgear Common […]

Product overview

KYN28A-12(Z)(GZS1) armored withdrawable AC metal-enclosed switchgear (hereinafter referred to as “switching device”), suitable for three-phase AC The 50Hz power system is used to receive and distribute electrical energy and control, protect and monitor the circuit.
This product conforms to the standard: GB3906 “3.6-40.5KV AC metal-enclosed switchgear and control equipment”, GB /T11022 “High-voltage switchgear Common technical requirements for equipment and control equipment standards”, IEC60298 “AC metal-enclosed switchgear and control equipment with rated voltage above 1KV and below 52KV “Preparation”, DL/T404 “Technical Conditions for Ordering Indoor AC High Voltage Switchgear”.

Model meaning

● Install a vacuum circuit breaker
● Rated voltage (KV)
● Design Number
● indoor
● Withdrawable
● Armoured

Normal use conditions

1. Ambient air temperature: the highest temperature is 40°C, the lowest temperature is -15°C.
2. Humidity conditions: daily average relative humidity: ≤95%, daily average water vapor pressure does not exceed 2.2Kpa; Monthly average relative humidity: ≤90%, monthly average water vapor pressure does not exceed 1.8Kpa;
3. Altitude: 1000m and below.
4. Earthquake intensity: no more than 8 degrees.
5. The surrounding air should not be significantly polluted by corrosive or combustible gas, water vapor, etc.
6. There is no frequent severe vibration place.
7. When used under normal environmental conditions exceeding GB3906, it shall be negotiated by the user and the manufacturer;

Technical parameters 

ProjectUnitData
Rated voltageKV3.6、7.2、12
Rated frequencyHz50
Circuit breaker rated currentA630、1250、1600、2000、2500、3150、4000
Rated current of switchgearA630、1250、1600、2000、2500、3150、4000
Rated short-time withstand current (4s)KA16、20、25、31.5、40、50
Rated peak withstand current (peak value)KA40、50、63、80、100、25
Rated short-circuit breaking currentKA16、20、25、31.5、40、50
Rated short-circuit making current (peak value)KA40、50、63、80、100、25
Rated insulation level1 min power frequency withstand voltageBetween poles, between poles to groundKV24、32、42
FractureKV24、32、48
Lightning impulse withstand voltage(peak value)Between poles, between poles to groundKV40、60、75
FractureKV46、70、85
Protection level The shell is IP4X, and when the door of the next door and circuit breaker room is opened, it is IP3X
Note: 1. The short-circuit capacity of the current transformer is considered separately;
2. The technical parameters of ZN63A-12 are detailed in the corresponding samples of our company.

Product structure characteristics

1. Switchgear structure (see Figure 1).
2. Completely metal armored, assembled structure, wide combination scheme.
3. The cabinet body is made of imported aluminum-zinc coated thin steel plate, processed by MINGE machine tool, and adopts advanced multifolding technology, connected with rivet nuts and high-strength bolts, and has high precision and light weight. High strength, strong versatility of parts.
4. It can be equipped with VS1-12 series or imported VD4 series vacuum circuit breakers, with wide applicability, high reliability, and long-term maintenance-free.
5. The handcart is equipped with working and testing positions, and each position has positioning and display devices, which is safe and reliable.
6. All kinds of handcarts are changed according to modular building blocks to ensure that cars of the same specification can be freely interchanged, and cars of different specifications are absolutely not allowed to enter.
7. Earthing switch installation method: (1) Installed in the middle of the cabinet (front-mounted) to facilitate double-sided maintenance after the cabinet (Figure 1-a). (2) Installed at the back of the cabinet (rear-mounted) to save space and area against the wall (Figure 1-b).
8. Current transformer installation method: (1) The cable room at the rear of the cabinet is installed in the front; (2) The large bent plate is hoisted at the bottom.
9. Up to 9 single-core cables can be installed in the cable room.
10. Each high-pressure chamber has a pressure relief channel to ensure personal safety.
11. The highly reliable interlocking device fully meets the “five prevention” safety requirements.
12. The handcart is transported by a special carrier, which is easy to operate and flexible.
13. The front and rear doors are equipped with observation windows, which can facilitate the observation of the working status of the indoor components

A. Busbar room

B. Circuit breaker handcart room

C. Cable room

D. Relay instrument room,

1. Shell

2. Branch bus

3. Bus bushing

4. Main bus

5. Static contact device

6. Contact box

7. Current transformer

8. Grounding switch

9. Cable

10. Lightning arrester

11. Ground bus

12. Loading and unloading partitions

13. Partition (trap)

14. Secondary plug

15. Circuit breaker handcart

16. Heating device

17. Withdrawable horizontal partition

18. Ground operating mechanism

19. Bottom plate

20. Pressure relief device

21. Control wire duct

Technical parameters

Height B 2300(2200)
Height ARated current of branch small busbar ≤1250A, thermal stability current 40KA800(650)
Rated current of branch small busbar ≥1600A1000
Height CCable in and out1500
Overhead incoming and outgoing lines1660

Dimensions 

(mm)Table      3(mm)表3
Cabinet width ACabinet depth BL1L2L3L4
8001500 cable530630150490
1660 overhead530630310650
10001500 cable730830150490
1660 overhead730830310650

Order notice

1. The main circuit diagram number, purpose and single-line system diagram, rated voltage, rated current, rated short-circuit breaking current, distribution room layout and switchgear arrangement diagram, etc.
2. Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices.
3. The model, specification and quantity of the main electrical components in the switchgear.
4. If the busbar bridge connection is required between switchgear or the incoming cabinet, the rated current carrying capacity of the busbar bridge, the span of the busbar bridge, the height from the ground and other specific requirements data should be provided.
5. When the switchgear is used under special environmental conditions, it should be explained in detail when ordering.
6. Other special requirements